required shaft equipment


  • 2015 INTERNATIONAL BUILDING CODE (IBC) | ICC DIGITAL CODES

    Conveyors and related equipment connecting successive floors or levels shall be enclosed with shaft enclosures complying with Section 713. 3004.3.2 Conveyor safeties. Power-operated conveyors, belts and other material-moving devices shall be equipped with automatic limit switches that will shut off the power in an emergency and automatically ...

  • LABORATORY SAFETY DESIGN GUIDE

    equipment and allow for circulation of materials on carts, etc. 5. Common corridors shall not be programmed for laboratory operations. For more information on use of corridors see the Corridor Policy Focus Sheet. 6. Equipment corridors shall be provided with a system designed to allow for securing equipment to prevent movement during an earthquake.

  • The Importance of Motor Shaft Alignment

    Flexible couplings also can reduce vibration transmitted from one piece of equipment to another, and some can insulate the driven-equipment shaft against stray electrical currents. Even flexible couplings have alignment requirements, defined in the instruction sheet for the coupling.

  • CGC SHAFT WALL SYSTEMS

    Elevator shafts Ideal for elevator shafts since the walls can be constructed from one side, leaving the shaft free of scaffolding. This allows elevator equipment to be installed simultaneously. Stair shafts Accommodates stair shafts by allowing both sides of the wall to be finished when required. For added

  • OSHA Machine Guarding Standards

    Safety Standard for Guarding of Machinery and Mechanical Power Transmission Apparatus. The OSHA standards on general guarding of machinery and mechanical power transmission apparatus (29 CFR 1910.212 and 1910.219) are very broad and general minimum guarding standards, one of which was predicated on the 1970''s version of the ANSI/ASME B15.1 standard, which itself had undergone …

  • Safeguarding Machinery and Equipment

     · protects workers when machinery or equipment is shut down for maintainance (including repairs and clearing jams). In all cases, training and supervision are essential to ensure worker safety around machinery. For information on WorkSafeBC requirements for locking out equipment, please see the WorkSafeBC booklet Lockout. • • • •

  • Bent Shaft Straightening

    Bent shafts caused by assembly stack-up stresses are usually not correctable by simply straightening the shaft itself. The assembly needs to be analyzed as a complete unit, and corrected accordingly. Sometimes, a change in the fits between the shaft and its mating components is required to accomplish the straightness needed.

  • How to calculate the shaft diameter from the torque ...

     · When a shaft is transmitting a power from driver equipment to the driven equipment, It is necessary to calculate the shaft diameter from the torque based on the maximum torque that can be transferred through the shaft or the maximum amount of twist in the shaft. Otherwise, the shaft may not satisfy the functionality of the equipment.

  • NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

    The equipment is required to be capable of functioning safely in the presence of an explosive atmosphere, and to be safe either ... an air circulated fan or a pump shaft. Some items of equipment will be designed to work across a boundary between zones. For example, in industrial applications where ...

  • MSHA

    Ongoing routine maintenance of the slope or shaft or routine maintenance of equipment installed in the slope or shaft would fall under Part 75 standards. An approved slope or shaft construction plan under Part 77 will not be required if Part 75 standards are complied with.

  • OSHA Requirements: Machine Guarding

     · General Requirements. 29 CFR 1910.212 (a) (1) states that one or more methods of machine guarding must be used to protect operators and other employees from hazards, including those created by point of operation, in-running nip points, rotating parts, flying chips and sparks.

  • Article 440 Air Conditioning and Refrigerating Equipment

     · These have no external shaft or shaft seals, and the motor operates in the refrigerant. Article 440 does not cover such appliances as room air-conditioners, refrigerators and freezers, drinking water coolers, or beverage dispensing machines, because these are appliances and must comply with Article 422.

  • Tillage Equipment Information Sheet

    NRCS Missouri 3 September 2007 Tillage Equipment Information Sheet Conservation Practice Information Sheet (IS-MO344) Disk Harrows – concave cutting blades mounted on a common shaft to form a gang; leveling tillage tool while sizing and burying residue; surface is smooth and runoff is likely to occur; may have primary tillage gang (front) and

  • Repair Tools

    Mitchell Golf Equipment Company 1001 Industrial Blvd Albion, MI 49224 United States

  • Installation and Parts Replacement Manual for Torque-Arm ...

    Minimum Required Shaft Length Reducer Size Taper Bushing Straight Bushing TXT/HXT 105 6-1/2 5-5/8 ... under average industrial operating Mount the reducer on the driven shaft as close to the equipment or bearing as practical. 5. of operation. At every oil change, drain reducer and flush with Line up the keyway in the bushing with the keyway in ...

  • 2015 INTERNATIONAL MECHANICAL CODE (IMC) | ICC DIGITAL …

    The shaft in which the duct is installed shall be constructed and fire-resistance rated as required by the International Building Code. 2. Dampers shall be prohibited in the exhaust duct, except as specified in Section 505.1. Penetrations of the shaft and ductwork shall be protected in accordance with Section 607.5.5, Exception 2. 3.

  • Steel Shafts | McMaster-Carr

    These shafts have keyways only on the ends, leaving a plain shaft in the center. Use the keyways with machine keys to transmit torque to gears, sprockets, and other keyed components. Use the middle of the shaft with bearings and other round-bore components.

  • Lifting Instructions Table of Contents Required Equipment ...

    Required Equipment In addition to standard mechanics tools, the following equipment is required: hoist, sling, eyebolts, arbor press, ... shafts, attach a "C" clamp to the extension to apply axial force, if required. Refer to Step 19 for bearing setting examples.

  • Falk Lifelign Gear Couplings

    shorter shaft spans can be accommodated, since no cover drawback is required . Types G52, GV52 Double or single engagement brakewheel and disc brake couplings are used for applications such as cranes, hoists and conveyors . Brakewheel and disc brake couplings accommodate misalignment between connected equipment and eliminate the need for

  • A Practical Guide to Shaft Alignment

    Similar pieces of equipment are vibrating less or have longer operating life. Unusual high rate of coupling failures or wear. Excessive amount of grease or oil inside coupling guards. Shafts are breaking or cracking at or close to the inboard bearings or coupling hubs. Good shaft alignment practice should be a key strategy in the

  • Vertical Exit Enclosures | UpCodes

    Equipment and ductwork for exit enclosure ventilation necessary for independent pressurization shall comply with one of the following items: 1. Such equipment and ductwork shall be located exterior to the building and shall be directly connected to the exit enclosure by ductwork enclosed in construction as required for shafts. 2.

  • Mine Shaft Sinking Equipment

     · Under miscellaneous equipment may be listed that required for framing shaft timber, for pouring concrete linings (concrete mixer, steel or wooden forms, and pipe, hose, or buckets for lowering concrete), and equipment for special shaft-sinking …

  • Selection and Replacement of Packing

    shaft speed approaches 2000 FPM, the amount of leak-age required will need to be increased. Metal packing, or packing with metal cores or combina-tions of synthetics and metals. Because high gland pressures will be required to control leakage, there will be high temperature where the pack-ing meets the shaft. Therefore, packing that will work

  • Shaft Enclosures | UpCodes

    Shafts that do not extend to the bottom of the building or structure shall comply with one of the following:. They shall be enclosed at the lowest level with construction of the same fire-resistance rating as the lowest floor through which the shaft passes, but not less than the rating required for the shaft enclosure.; They shall terminate in a room having a use related to the purpose of the ...

  • Agricultural Machinery Management (ACIS)

    Power-takeoff (PTO) power is power required by the implement from the PTO shaft of the tractor or engine. Typical PTO power requirements can be determined using rotary power requirement parameters available from a number of sources. Implement power take-off …

  • Chapter 5

     · Although the capabilities of the drilling machine are critical to the ability of the constructor to complete the drilled shaft excavation to the size and depth required, the choice of drilling tools is often as (or more) important to the productivity of the …

  • Drilled Shafts: Tools & Equipment

     · Drilled Shafts: Tools & Equipment. on November 22, 2016. Drilled shafts are often used for different types of construction projects such as bridges, …

  • Elevator machine room rating | The Building Code Forum

     · Some in the office claim that if the shaft is not required to be rated then the adjacent room need not be but I can not find that in the code. To me the shaft is to protect the building from the spread of fire and the room is to protect the equipment that is conveying the elevator and its occupants- two totally different reasons for requiring ...

  • The Equipment Rules

    Throughout The Equipment Rules there are specific sections which are highlighted by blue shading. These sections are either direct statements of Rule 4 or contain specific requirements for equipment. These are the most important sections of The Equipment Rules and together constitute the specifications against which equipment is evaluated.

  • DRILLED SHAFTS

    casing is required through unstable soil, but the casing is able to be seated into the underlying foundation material such that water infiltration is stopped. This results in a casing being used through the unstable material, but the dry construction method is utilized for the remainder of the drilled shaft.

  • OSHA''s machine guarding requirements provide no exemption ...

     · The shaft''s diameters that can be used are 3-inch, 4-inch and 4 5/16-inches. The length of the exposed shaft is approximately 7 inches. The shafts revolutions range from 17 to 54 per minute (rpm). The measurement from the outside of the motor mounts to the outside of the shaft varies from 8 inches to 13 inches depending on the equipment.

  • The Material And Process Requirements For Driving Shaft ...

     · A composite shaft has withstood 106 cycles of maximum torque as compared with the 104 cycles typically required of a steel shaft. Shafts were fitted to cars to gain road experience and demonstrate satisfactory operations. Such testing demonstrates that the component really works and meets all the criteria required.

  • 40 CFR § 63.1363

    (a) General equipment leak requirements. (1) The provisions of this section apply to "equipment" as defined in § 63.1361.The provisions of this section also apply to any closed-vent systems and control devices required by this section. (2) Consistency with other regulations. After the compliance date for a process, equipment subject to both this section and either of the following will be ...

  • CHAPTER 21 Mechanical Design of Mixing Equipment

    ings are found in all types of rotating equipment. Some type of seal around the rotating shaft is required for closed-tank operation and the type depends on degree of seal required, operating pressure, and operating temperature. The shaft for a mixer, especially a large one, involves significant mechanical

  • Elevator Shaft Smoke Detectors

     · 6.15.3.6 Smoke Detectors shall not be installed in un-sprinklered elevator hoistways unless they are installed to activate the elevator hoistway smoke relief equipment. I know this is a very old edition of NFPA 72; the Code Officials we work with do not require smokes in the hoistway, unless we have a smoke relief damper at the top.

  • Shaft Enclosure Required | UpCodes

    A shaft enclosure is not required for automobile ramps in open and enclosed parking garages constructed in accordance with Sections 406.3 and 406.4, respectively. A shaft enclosure is not required for floor openings between a mezzanine and the floor below. A shaft enclosure is not required for joints protected by a fire-resistant joint system ...